How to reduce the vibration noise of the screw air compressor body
Time:
2022-07-08
Controlling the noise of the air compressor controls the vibration. The vibration of the air compressor is mainly transmitted to the outside through the foundation and piping system. Vibration control mainly adopts vibration isolation control. The main measures are as follows: 1. Use vibration isolators The vibration isolator forms an elastic connection between the air compressor and the foundation, and reduces the amplitude to achieve vibration isolation, which is the key link of vibration isolation. 2. Adopt vibration isolation joint suspension foundation The vibration isolation joint suspended foundation cuts off the way the air compressor vibration is transmitted to the soil. The vibration isolation joint is 150-200mm wide, filled with dry sand, dry sand and industrial felt are laid under the foundation, and the thickness of the felt is 20-40mm. 3. Adopt vibration isolation trench In some cases, trenching on the ground can be adopted to cut off the vibration mainly propagating by surface waves along the ground. The above is the editor's personal opinion on how to reduce the vibration and noise of the screw air compressor body. I hope it will help you when choosing a screw air compressor. Because each air compressor manufacturer has differences in production batches and models, when the machine has problems or needs maintenance and inspection, everyone should contact the air compressor manufacturer, which can easily solve the problem of air compressor production. The process always encounters problems.
Controlling the noise of the air compressor controls the vibration. The vibration of the air compressor is mainly transmitted to the outside through the foundation and piping system. Vibration control mainly adopts vibration isolation control. The main measures are as follows:
1. Use vibration isolators
The vibration isolator forms an elastic connection between the air compressor and the foundation, and reduces the amplitude to achieve vibration isolation, which is the key link of vibration isolation.
2. Adopt vibration isolation joint suspension foundation
The vibration isolation joint suspended foundation cuts off the way the air compressor vibration is transmitted to the soil. The vibration isolation joint is 150-200mm wide, filled with dry sand, dry sand and industrial felt are laid under the foundation, and the thickness of the felt is 20-40mm.
3. Adopt vibration isolation trench
In some cases, trenching on the ground can be adopted to cut off the vibration mainly propagating by surface waves along the ground.
The above is the editor's personal opinion on how to reduce the vibration and noise of the screw air compressor body. I hope it will help you when choosing a screw air compressor.
Because each air compressor manufacturer has differences in production batches and models, when the machine has problems or needs maintenance and inspection, everyone should contact the air compressor manufacturer, which can easily solve the problem of air compressor production. The process always encounters problems.
Relevant news